Fixed Fire Fighting Systems |
|
|
|
|
|
|
We represent Danfoss Semco for High-Technology fire fighting solutions for marine applications
Your total solution provider
Danfoss Semco has the experience and technological knowledge to provide you with fire fighting solutions designed in
accordance with IMO/SOLAS regulations and many classification societies and national authorities. Our team specialises in meeting your specifications, no matter how specific, to supply precisely the system you need.
|
|
|
Sem-Safe Water Mist System
The Sem-Safe Water Mist System is unique. Water is forced through micro nozzles at very high pressure to create a water mist with the most effective fire fighting drop size distribution. The extinguishing effects give optimum protection by cooling, due to heat absorption, and inerting due to the expansion of water by over 1,700 times when it evaporates.
The Sem-Safe Water Mist System provides better protection for personnel and surroundings and minimises potential water damage, as the majority of the water mist evaporates. The Sem-Safe Water Mist System is available for total flooding, local applications and deep fat fryers, and also as a high pressure or low pressure system. |
|
|
|
|
|
|
|
High and Low Pressure CO2 System
High and Low Pressure CO2 System CO2 systems are used as total flooding systems in engine rooms, machinery spaces and cargo holds. The HP system consists of a number of CO2 cylinders, whose outlets are connected to a common manifold. From there, the CO2 is directed, via selector valves, into the various protected spaces. If the protected space is large, a high number of cylinders are required. These can be replaced by a single CO2 tank, saving approximately 50% in weight and installation costs. The tank contains CO2 cooled to -18°C. The tank, refrigerators, distribution valves, controls, etc., are supplied pre-wired and ready assembled on a steel frame.
* CO2 High Pressure Systems
* Low Pressure CO2 Systems |
|
|
|
|
|
|
|
Foam Fire Extinguishing System
High and Low Pressure CO2 System Foam used in fire protection is an aggregate of air-filled bubbles formed from aqueous solutions, and is of lower density than the lightest flammable liquids. It is mainly used to form a coherent floating blanket on flammable and combustible liquids to prevent or extinguish fires by excluding air and cooling the fuel. It then prevents re-ignition by suppressing the formation of flammable vapours, and also adheres to surfaces, providing a degree of exposure protection from adjacent fires.
Foam can be used as a fire prevention, control or extinguishing agent for flammable liquid in tanks or processing areas. |
|
|
|
|
|
|
|
Dry Chemical Powder Fire Extinguishing System
Dry Chemical Powder Fire Extinguishing System When introduced directly to a fire, dry chemical powder extinguishes flames almost immediately. Dry chemical powder is intended for use in extinguishing fires involving bulk chemical agents and liquefied gases. Our dry systems are developed to meet the increasing demand for large capacity systems for the protection of ships carrying LNG/LPG and certain chemicals or agents in bulk. |
|
|
|
|
|
Tested and approved
DANFOSS SEMCO'S fire fighting systems are recognised by all leading classification societies and national maritime
authorities, including ABS, BV, DNV, FM, GL, KRS, LRS, NK, PRS, CCS, RMRS, RINA and others.
Danfoss Semco has experience in the design, engineering and delivery of thousands of marine fire fighting systems all over the world, in accordance with SOLAS/IMO regulations, and approved for each ship by the relevant classification society and national authority.
Danfoss Semco operates a QA system in accordance with EN ISO 9001:2000, and we are certified by DNV. Our on-going
internal training programs make our employees, naval architects, sales engineers, project managers, service engineers, and all support staff fully qualified to handle all our fire fighting systems for the marine industry.
Container Vessels - Bulk Carriers - Multi-purpose Vessels |
|
|
|
|
Engine Room: HP CO2 , local protection water mist system Cargo Holds: HP CO2 , smoke detection system
Galley: HP CO2 duct, Deep Fat Fryer water Mist system |
|
|
|
|
|
|
Oil-Product/Chemical Tankers/ LNG-LPG Gas Tankers |
|
|
|
|
Engine Room: CO2 local protection water mist system
Cargo Holds: Foam, dry chemical system
Galley: HP CO2 duct, Deep Fat Fryer water mist system |
|
|
|
|
|
|
RO-RO/PCC/PCTC |
|
|
|
|
Engine Room: LP CO2 , local protection water mist system Cargo Holds: LP CO2 , Drencher system Galley: HP CO2 Duct, Deep Fat Fryer water mist system |
|
|
|
|
|
|
Passenger/Cruise Vessels |
|
|
|
|
Engine Room: HP water mist system, HP CO2 , local protection water mist system Accommodation: HP water mist system Accommodation & Car Decks: Sprinkler/ drencher system
Galley: HP CO2 , duct , Deep Fat Fryer
water mist system |
|
|
|
|
|
|
Navy Vessels |
|
|
|
|
Engine Room: Argonite, HP CO2 , Novec 1230, HP water mist system Accommodation: HP water mist system Tech. Rooms: Argonite, Novec 1230 Helideck: Foam System Galley: HP CO2, duct, Deep Fat Fryer
water mist system |
|
|
|
|
|
|
Supply Vessels and Tugs |
|
|
|
|
Engine Room: Argonite, HP CO2 , HP water mist system Deck: Foam monitors, sprinklers for
chemical tanks. Helideck: Foam system Galley: HP CO2 , duct, Deep Fat Fryer
water mist System. |
|
|
HP: High Pressure LP: Low Pressure |
|
For more information please visit www.danfoss-semco.com. |
|
|
|
|
|
Disclaimer :
Information and photographs in this catalogue are an overview of OEM range products. For more / exact details please refer to original OEM catalogue. Products names, logos, brands and other trademarks featured or referred to within this document are the property of their respective trademark holders. |
|